Advantage Outdoor Air-Cooled Central Chillers

5 to 210 Tons, Single & Dual Zone

A weatherproof plant chiller on a pad outside the building

Overview

A weatherproof Advantage plant chiller that sits on a pad outside the building - no mechanical room, no tower.

Advantage outdoor air-cooled central chillers arrive fully charged, tested and ready to run: set the unit on a pad, connect power and the process water piping, and fill the loop. There's no cooling tower to maintain and no mechanical-room space to find - the whole plant chiller lives outside on its own footprint.

Units are available as single-zone packages, delivering one chilled-fluid temperature to the whole plant, or dual-zone packages that produce two independent fluid temperatures from one chiller frame - useful where part of the plant needs a colder process fluid than the rest, without running two separate chillers.

Capacity runs roughly 5 tons in the smallest single-zone models up to the low 200-ton range in the largest dual-zone units at typical 50°F leaving-fluid conditions. Colder leaving temperatures reduce the effective tonnage of any given frame, so confirm your required temperature before comparing models by tonnage alone.

See the OACS series for the full line of Advantage outdoor air-cooled packages on this page, 5 to 210 tons, single- or dual-zone, with complete part numbers and specs.

Single zone
~5 to 55 tons
Dual zone
~10 to 190+ tons
Rated at
50°F leaving fluid
Installation
Pad, power, piping

Single Zone or Dual Zone

Capacity is quoted at typical 50°F leaving-fluid conditions; a colder setpoint reduces it.

Configuration Capacity Range Notes
Single Zone ~5 to 55 tons One chilled-fluid temperature plant-wide
Dual Zone ~10 to 190+ tons Two independent fluid temperatures from one frame

Weatherproof by Design

An Advantage outdoor air-cooled chiller is built for its environment from the frame up: powder-coated or galvanized cabinetry, weather-protected electrical enclosures, and controls rated for the ambient extremes of the install site. In climates with hard winters, low-ambient controls keep the condenser fans and refrigerant circuit operating correctly at cold outdoor temperatures rather than shutting the unit down or damaging components; in hot climates, the condenser is sized against the region's peak design-day ambient, not just the average.

Dual-zone models are the more specialized selection - they earn their premium when a plant genuinely needs two different process temperatures (for example, a colder fermentation loop and a warmer general process loop) and would otherwise be running two separate outdoor units. If the whole plant runs on one temperature, a single-zone unit is the simpler and less expensive package.

Outdoor Site Details

Send These With Your Outdoor Chiller Request

An outdoor unit is selected against the weather at your pad as much as the load inside, so include the site along with the process:

  • Cooling load in tons, or flow rate and temperature rise
  • One leaving temperature or two (dual zone), and any glycol percentage
  • The site's summer design high and winter design low
  • Pad distance from the main header, and any noise limit at the property line
  • Electrical service at the pad, and how a crane or truck reaches it
Request a Quote

Call and talk it through with an engineer: 1-805-484-2992

Picking the pad: distance, sound, snow and power

As far as the pump head and the supply temperature can tolerate. Every foot of pipe adds friction: at a common design rate of about 4 feet of head per 100 feet, a pad 150 feet out adds 300 feet of supply and return, roughly 12 feet of head before fittings, which the built-in pump must cover on top of the machines' own pressure drop. Exposed supply pipe also gains heat in summer sun and sweats whenever it runs colder than the outdoor dew point, often in the 60s°F on humid days. Put the pad near the main header and send us the run length.

Possibly, if the pad faces homes. In open ground, fan noise falls about 6 dB each time the distance doubles, so a unit producing 75 dBA at 30 feet is still near 63 dBA at 120 feet - above many nighttime residential limits. A building between the unit and the neighbor helps a great deal; a hard wall directly behind the fans can make it worse by reflecting sound outward. Check the local ordinance before the pad is poured, put the unit on the side of the building away from houses, and tell us the limit you must meet.

Yes, anywhere with real winters. Drifting snow can block the coil intake and bury the base, and a strong wind blowing straight into the fan discharge cuts airflow. Raise the pad above typical snow depth, keep the unit clear of roof edges that shed snow and ice, and stay out of the drift zone beside tall walls. The easy first-winter mistake is putting the pad exactly where the plow driver piles snow. Low-ambient controls handle cold air well, but nothing in the controls can clear a coil packed solid.

For early planning, allow roughly 1.2 to 1.3 kW per ton for an air-cooled scroll package including condenser fans, plus the process pump, then confirm from the nameplate once an Advantage model is selected. At that rate a 100-ton unit draws about 125 kW, which at 460 volts three-phase is around 175 amps of running current; the feeder is then sized from the unit's minimum circuit ampacity, which is higher. Check the panel and the utility transformer early, because a new electrical feed can take longer to arrive than the chiller.