Advantage BC-SCC Tank Control Cabinets

2 to 8 Tanks, One Central Glycol Loop

One central glycol chiller, many independently controlled tanks

Advantage BC-SCC tank control cabinet with solenoid valve and thermocouple

BC-SCC Series

PRODUCT TYPE CAPACITY COOLING
Tank Control Cabinet Control Accessory 2 – 8 Tanks None

Specifications


Configuration & Size

Tanks Controlled:
2 to 8 per Cabinet
Standard Models:
7
Enclosure:
Cabinet
Type:
Control Accessory
Brand:
Advantage

Construction

  • No Refrigeration Circuit - Not a Chiller
  • Runs Off One Central Glycol Loop
  • Independent Temperature per Tank

Ratings

  • Voltage: 110/115V
  • Phase: Single Phase
  • Frequency: 60 Hz

BC-SCC Tank Control Cabinets

Several Tanks, One Glycol Chiller

A wall-mount control cabinet, not a chiller — distributes one central glycol chiller across multiple independently controlled brewery tanks.

BC-SCC is not a chiller — it's a wall-mount electrical control cabinet that sits between one central glycol chiller and 2 to 8 brewery tanks, giving each tank its own independent temperature control from a single central glycol loop. Seven standard models cover 2 through 8 tanks, one control channel per tank.

Each channel reads its own thermocouple temperature sensor mounted on the tank and switches a 1/2" solenoid valve to admit chilled glycol into that tank's jacket whenever it calls for cooling — an adjustable set point and an actual-temperature readout per channel let an operator see and set every tank independently from one panel, rather than running one glycol loop at a single fixed temperature for every tank in the room. Optional high-temperature lockout and an emergency stop button are available across the line.

The cabinet runs on standard single-phase 110/115V power — no three-phase service is required for the control panel itself, separate from whatever power the chiller feeding it needs. A BC-SCC doesn't produce any cooling capacity of its own: it makes one properly sized central glycol chiller (see the BG series) usable across multiple tanks running at different temperatures and schedules, instead of forcing every tank onto the same loop temperature or buying a separate chiller per tank.



Distributes one glycol chiller's loop to two through eight tanks, each held at its own temperature.

Request a Quote

BC-SCC Series Applications

Brewery Fermentation Tank Control
Brewery Fermentation Tank Control
Bright Tank Temperature Control
Bright Tank Temperature Control
Multi-Tank Glycol Distribution
Multi-Tank Glycol Distribution
Dairy & Beverage Tank Farms
Dairy & Beverage Tank Farms

One glycol chiller feeding a BC-SCC control cabinet that distributes to four tanks

One Chiller, Several Tanks, Independent Temperatures

A single central glycol chiller can carry the combined load of several fermentation or bright tanks, but only if each tank can call for cooling on its own schedule and its own set point. BC-SCC is the piece that makes that possible — without it, every tank on the loop runs at whatever temperature the chiller itself is set to, with no per-tank control.

Tell us how many tanks your running and their individual temperature targets, and we'll confirm both the right BC-SCC model and the central chiller sized to feed it. Call: 1-805-484-2992

Choosing a BC-SCC model is simply a tank count — 2 through 8 independently controlled channels, one per tank. The harder question is sizing the central glycol chiller that feeds it, which depends on the combined heat load and duty cycle of every tank on the loop, not just the tank count.

See the BG series for the chiller itself, or go straight to Request a Quote with your tank count and target temperatures and we'll size both together.

Common FAQs

No. It's a wall-mount electrical control cabinet with no refrigeration of its own; it distributes cooling from a separately sized central glycol chiller across multiple tanks. See the BG series for the chiller itself. On a quote the cabinet always appears beside a chiller, never in place of one, and adding it changes nothing about the total load the chiller sees - the tanks still draw their combined heat from the same loop.

Up to eight. Seven standard models cover 2 through 8 tanks, one independent control channel per tank, each with its own thermocouple and 1/2" solenoid valve. A cellar that grows past eight tanks takes a second cabinet on the same glycol loop rather than a bigger one, so it can make sense to split tanks by area - fermenters on one cabinet, bright tanks on another - which also keeps the wiring runs to each tank shorter.

No. A BC-SCC only distributes and controls cooling that a central glycol chiller already produces; undersize the chiller feeding it and every tank competes for the same limited cooling regardless of how the cabinet is configured. Eight 15-barrel fermenters in active fermentation draw about 7,200 BTU/hr. Crash two of them together from 75°F to 35°F over 18 hours and those two alone add about 17,000 BTU/hr. The cabinet will happily open both crash valves at once; whether the glycol stays cold enough is entirely the chiller's job.

Standard single-phase 110/115V, 60 Hz power for the control panel itself - no three-phase power required, apart from whatever power the chiller feeding it needs. The bigger wiring job is in the field: every channel needs a sensor lead and a valve circuit run out to its tank. Extend thermocouples only with matching thermocouple-grade wire, because ordinary copper hookup wire creates an extra junction that can put a tank's reading a degree or more off.

By opening and closing one jacket valve. Each channel reads a thermocouple on its tank and, when that tank calls for cooling, energizes a 1/2" solenoid valve that lets chilled glycol into the jacket. The panel shows each channel's adjustable set point and actual temperature, so an operator can check and change every fermenter or bright tank from one cabinet. The loop itself stays at the central chiller's setpoint; only each tank's valve cycles. Mount the sensor in a thermowell reading the beer, not against the jacket, or it reads glycol, cycles the valve constantly and leaves the tank warm.

Three things, starting with the tank count, which is the model: BC-SCC-2T through BC-SCC-8T, one channel per tank. If more tanks are planned, a cabinet with unused channels avoids replacing the panel later. Second, whether you want the optional high-temperature lockout. Third, whether you want the optional emergency stop button. Also confirm how the thermocouple and the 1/2" solenoid valve will mount on each tank's jacket piping. Send the tank count, each tank's target temperature and the options through Request a Quote; we'll pair the Advantage cabinet with the glycol chiller feeding it.

Whatever the central chiller delivers; the cabinet only opens and closes valves. BG chillers are built to deliver 25-30°F glycol, and Advantage specifies inhibited propylene glycol at 30-35% for 25°F, mixed so it freezes roughly 25°F under the lowest setpoint. Every tank set point on the cabinet has to sit above the loop temperature, because a jacket can only pull a tank toward the glycol supply temperature. A 33°F crash target on 28°F glycol leaves just 5°F of driving force, so the last few degrees come slowly. Check the mix with a refractometer on a schedule, since a diluted loop can freeze the chiller's evaporator.

Tank Control Cabinets

Model Tanks ControlledVoltage
BC-SCC-2T 2110/115 volt
BC-SCC-3T 3110/115 volt
BC-SCC-4T 4110/115 volt
BC-SCC-5T 5110/115 volt
BC-SCC-6T 6110/115 volt
BC-SCC-7T 7110/115 volt
BC-SCC-8T 8110/115 volt

Quote Request Form:

Questions?

1-805-484-2992

Quotes - Engineering - Sales