| Product | Type | Tanks Controlled | Voltage |
|---|---|---|---|
| Tank Control Cabinet | Control Accessory | 6 | 110/115V, 1-Phase |
Note: Unit pictured is representative of standard unit and may not exactly depict p/n BC-SCC-6T as shown on this page.
The BC-SCC-6T is a wall-mount electrical control cabinet, not a chiller — it distributes cooling from one central glycol chiller across 6 independent brewery tanks, one control channel per tank. Each channel reads its own thermocouple temperature sensor and switches a 1/2" solenoid valve to admit chilled glycol into that tank's jacket whenever it calls for cooling, with an adjustable set point and an actual-temperature readout per tank so an operator can see and set every tank independently from one panel. It runs on standard single-phase 110/115V power — no three-phase service required for the control panel itself. The BC-SCC-6T makes one central glycol chiller usable across multiple tanks; it doesn't produce any cooling of its own, and it isn't a substitute for sizing the chiller that actually feeds it.
• Individual controls for each tank
• Adjustable set point with actual temperature readout
• Tank cooling on/off switch
• Power indicator light
• Main panel on/off switch
• 1/2" solenoid valves (factory or field supplied)
• Glycol temperature monitoring with high temperature tank cooling lockout circuit
• Emergency stop button